Batch Tank Sizing Calculator
A batch tank is sized to hold one or more batches of liquid at a working fill level, plus any heel (dead) volume that stays in the tank between batches. This calculator estimates the working liquid volume from the batch size and number of batches, adds the heel, divides by the working fill fraction to get the geometric tank volume the vessel must provide, and applies an optional contingency allowance. It is a preliminary sizing estimate only — it is not a production schedule model, not a cleaning-validation model, and not a mechanical design.
Calculator
Preliminary estimate only. Not a production schedule model, cleaning-validation model, or mechanical design. Does not model residence time, reaction completion, mixing time, heat-up/cool-down, filling/draining constraints, CIP, foam, or overflow. Final tank sizing requires the operating sequence, cleaning philosophy, site standards, mechanical design, and qualified engineering review.
Formulas
Diagram
Worked example
A batch tank must hold 2 batches of 10.0 m³ each at an 80% working fill, with a 1.0 m³ heel and a 10% contingency allowance. What geometric tank volume is required?
- 01V_working = batch_volume × number_of_batches = 10.0 × 2 = 20.0 m³
- 02V_liquid = V_working + heel = 20.0 + 1.0 = 21.0 m³
- 03V_geometric = V_liquid / fill_fraction = 21.0 / 0.80 = 26.25 m³
- 04V_design = V_geometric × (1 + 10/100) = 26.25 × 1.10 = 28.875 m³
Working liquid volume = 20.0 m³; liquid required incl. heel = 21.0 m³; geometric volume = 26.25 m³; design tank volume ≈ 28.88 m³.
FAQ
Why divide by the fill fraction?
What is the heel / dead volume?
Does this guarantee enough residence or reaction time?
Is the contingency allowance the same as freeboard?
Related conversions
Built and reviewed by a practising process engineer. About ProcessConvert →